GPGATE GPF12120 12V 120Ah Telecom Battery used for the ups uninterruptible power supply emergency power supply & Telecom communication server group

 Telecom battery Commercial UPS/TELECOM 

GPGATE® Telecom battery outperform traditional AGM and Gel batteries and are a resilient battery solution for ups uninterruptible power supply and telecom communication server group applications. The batteries exceed rigorous safety tests and incorporate design features that adhere to discharge performance, stability and long duration cyclic current draws.

 

MECHANICAL SPECIFICATIONS

Industry Reference ISO9001
Length A (in/mm)
21.7
551
Width B (in/mm)
4.3
109
Height C (in/mm)
9.4
239
Total Height D (in/mm)
9.4
239
Weight (lbs/kgs)
86
39
Terminal *
F13
Technology
UPS

NOTE 1: Dimensions have a ±2 mm (0.08 in) tolerance. Weights may vary.
NOTE 2: Refer to terminal guide on website for torque values.

PERFORMANCE SPECIFICATIONS

Amp Hours (AH)
10 HR
20 HR
120
135

ELECTRICAL SPECIFICATIONS

Voltage (V) 12
Internal Resistance (mΩ)
3.5
Short Circuit (A) (20°C / 68°F)
3200
Self-Discharge (20°C / 68°F)
2-3% per month
Charge Temperature
Min: -10°C (14°F) | Max: 50°C (122°F)
Storage Temperature
Min: -10°C (14°F) | Max: 50°C (122°F)

NOTE 3: Extra considerations must be given when designing systems for use at maximum temperatures.
NOTE 4: Internal Resistance is approximate.

5 HR: 1.75VPC; 10 HR: 1.80VPC; 20 HR: 1.80VPC. All at 30°C/86°F

FEATURES

Long life service

Over 12 years ‘Very Long Life’,High performance battery for critical UPS applications

Easy to use

Easy installation and maintenance through front connectors, lead-calcium grid for longer service life, electrolyte bound in glass fiber fleece (AGM technology) valve controlled design, nearly 100% oxygen recombination

Excellent ABS design

Impact and shatterproof plastic housing made of ABS, standard FR housing, excellent airtight design to avoid the solidification of conductive liquid

Dis-charging and recycle energy

Low self-discharge, 3% per month at 20°C, fast recovery after deep discharge, operation in any position (except permanently overhead)

CERTIFIED QUALITY

GB/T 22199-2008 、GB/T18332.1-2009 ;Passed ISO9001、ISO14001、ISO18001、CE certificate

SHIPPING CLASSIFICATION

  • Classified as a nonspillable battery
  • Without restriction for transport by Sea (IMDG amendment 27)
  • Without restriction for transport by Air (IATA/ICAO provision 67)
  • Without restriction for transport by Ground (STB, DOT-CFR-HMR49)

Discharge Characteristics (25°C)

Effect of Temperature on Capacity

Charge Characteristic Curve For Standby Use

Effect Of Temperature On Long Term Life

Charging Characteristics (25°C)

Self-Discharge Characteristics

The Relationship for Charging Voltage and Temperature

Cycle Life on D.O.D (25°C)

NOTES

1. Due to self-discharge characteristics of lead-acid battery technologies, batteries should be top charged within 6 months of storage to ensure optimum performance, prevent sulphation and permanent capacity loss.

2. Charge profile recommendations correspond to battery voltages at 25°C (77°F). For temperatures below, adjust +5mVPC/°C (+3mVPC/°F). Temperatures above, adjust -5mVPC/°C (-3mVPC/°F). Temperature compensated charging helps ensure optimum battery runtime and life performance.

3. Charge profile recommendations depend on application and charger. IUI (or IUI with Pulse) is appropriate for applications that require frequent and deep discharges. IUU is appropriate for applications that are on standby and cycled less frequently.

4. IUI with Pulse algorithm uses a pulse termination criterion. The finish current is pulsed on and off in order to keep the battery voltage at a minimum while still reaching target overcharge. If average VPC exceeds U2 and the charger output has been on for more than 30 seconds, the output is shut off until VPC falls to U3.

5. IUI Charge Profile (if applicable), may have a continuous float phase added (2.27VPC).